Optional SW Licenses for ISONIC 2006

I2-SONIC - Inspection of Planar Butt Joints, Scanning from One Side, Complete Raw Data Capturing Order Code:
SWA 996600 XXX
  • Support of all A-Scan types (Full Wave / Neg Wave / Pos Wave rectification; RF) while scanning, recording and imaging defects
  • Support of Linear or DAC- , DGS- , TCG- normalized recording and imaging defects
  • FFT (Frequency Domain Signal Presentation) - additional feature for defects evaluation and / or pattern recognition
  • Testing Integrity / Coverage Imaging (Top View of Probe Manipulation Area) Showing of Actually Implemented Probe Trace
  • C-Scan (Top View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • B-Scan (Side View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • D-Scan (End View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • Versatile Color Palette for Defects Imaging
  • Postprocessing: Off-line Recovery and Play-Back of A-Scans; Echo Dynamic Pattern Recognition; Sizing of defects; Slicing and Filtering Images
  • Comprehensive Setup and Scanning Reporting, Direct Connection To any Type of USB or LAN Windows Printer
Required Accessories:
  • S 4030A or S 4030A HT
  • S 2040 B
  • S 4050 or S 4050 HT AND/OR S 4060 or S 4060 HT
  • S 70200 or S 70200 HT
  • Probe Holders for Angle Beam Probes to Be Used for Weld Inspection
Optional Accessories:
  • S 4010
  • S 799028 or S 799028 HT
  • SWA 996014
PLCROSS - Inspection of Planar Butt Joints, Scanning from Both Sides, Complete Raw Data Capturing Order Code:
SWA 996603
  • Support of all A-Scan types (Full Wave / Neg Wave / Pos Wave rectification; RF) while scanning, recording and imaging defects
  • Support of Linear or DAC- , DGS- , TCG- normalized recording and imaging defects
  • FFT (Frequency Domain Signal Presentation) - additional feature for defects evaluation and / or pattern recognition
  • Testing Integrity / Coverage Imaging (Top View of Probe Manipulation Area) Showing of Actually Implemented Probe Trace
  • C-Scan (Top View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • B-Scan (Side View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • D-Scan (End View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • Versatile Color Palette for Defects Imaging
  • Postprocessing: Off-line Recovery and Play-Back of A-Scans; Echo Dynamic Pattern Recognition; Sizing of defects; Slicing and Filtering Images
  • Comprehensive Setup and Scanning Reporting, Direct Connection To any Type of USB or LAN Windows Printer
Required Accessories:
  • S 4030A or S 4030A HT
  • S 2040 B
  • S 4050 or S 4050 HT AND/OR S 4060 or S 4060 HT
  • S 70200 or S 70200 HT
  • Probe Holders for Angle Beam Probes to Be Used for Weld Inspection
  • S 904050
Optional Accessories:
  • S 4010
  • S 799028 or S 799028 HT
  • SWA 996014
CIRCROSS - Inspection of Circumferential or Spiral Butt Joints, Scanning from Both Sides, Complete Raw Data Capturing, weld diameters 400 mm and above Order Code:
SWA 996604
  • Support of all A-Scan types (Full Wave / Neg Wave / Pos Wave rectification; RF) while scanning, recording and imaging defects
  • Support of Linear or DAC- , DGS- , TCG- normalized recording and imaging defects
  • FFT (Frequency Domain Signal Presentation) - additional feature for defects evaluation and / or pattern recognition
  • Testing Integrity / Coverage Imaging (Top View of Probe Manipulation Area) Showing of Actually Implemented Probe Trace
  • C-Scan (Top View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • B-Scan (Side View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • D-Scan (End View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • Versatile Color Palette for Defects Imaging
  • Postprocessing: Off-line Recovery and Play-Back of A-Scans; Echo Dynamic Pattern Recognition; Sizing of defects; Slicing and Filtering Images
  • Comprehensive Setup and Scanning Reporting, Direct Connection To any Type of USB or LAN Windows Printer
Required Accessories:
  • S 4030A or S 4030A HT
  • S 2040 B
  • S 4050 or S 4050 HT AND/OR S 4060 or S 4060 HT
  • S 70200 or S 70200 HT
  • Probe Holders for Angle Beam Probes to Be Used for Weld Inspection
  • S 904050
Optional Accessories:
  • S 4010
  • S 799028 or S 799028 HT
  • SWA 996014
SM_PIPE - Inspection of Butt Welds between Small Diameter Pipes (80 to 800 mm), Scanning from One Side, Complete Raw Data Capturing Order Code:
SWA 996605
  • Support of all A-Scan types (Full Wave / Neg Wave / Pos Wave rectification; RF) while scanning, recording and imaging defects
  • Support of Linear or DAC- , DGS- , TCG- normalized recording and imaging defects
  • FFT (Frequency Domain Signal Presentation) - additional feature for defects evaluation and / or pattern recognition
  • Testing Integrity / Coverage Imaging (Top View of Probe Manipulation Area) Showing of Actually Implemented Probe Trace
  • C-Scan (Top View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • B-Scan (Side View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • D-Scan (End View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • Versatile Color Palette for Defects Imaging
  • Postprocessing: Off-line Recovery and Play-Back of A-Scans; Echo Dynamic Pattern Recognition; Sizing of defects; Slicing and Filtering Images
  • Comprehensive Setup and Scanning Reporting, Direct Connection To any Type of USB or LAN Windows Printer
Required Accessories:
  • S 4030A or S 4030A HT
  • S 2040 B
  • S 4050 or S 4050 HT AND/OR S 4060 or S 4060 HT
  • S 70200 or S 70200 HT
  • Probe Holders for Angle Beam Probes to Be Used for Weld Inspection
  • S 89000
Optional Accessories:
  • S 4010
  • S 799028 or S 799028 HT
  • SWA 996014
LONGWELD - Inspection of Longitudinal Welds In Pipes, diameter 300 mm - 4000 mm, Scanning from Both Sides, Complete Raw Data Capturing Order Code:
SWA 996652
  • Support of all A-Scan types (Full Wave / Neg Wave / Pos Wave rectification; RF) while scanning, recording and imaging defects
  • Support of Linear or DAC- , DGS- , TCG- normalized recording and imaging defects
  • FFT (Frequency Domain Signal Presentation) - additional feature for defects evaluation and / or pattern recognition
  • Testing Integrity / Coverage Imaging (Top View of Probe Manipulation Area) Showing of Actually Implemented Probe Trace
  • C-Scan (Top View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • B-Scan (Side View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • D-Scan (End View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • Versatile Color Palette for Defects Imaging
  • Postprocessing: Off-line Recovery and Play-Back of A-Scans; Echo Dynamic Pattern Recognition; Sizing of defects; Slicing and Filtering Images
  • Comprehensive Setup and Scanning Reporting, Direct Connection To any Type of USB or LAN Windows Printer
Required Accessories:
  • S 4030A or S 4030A HT
  • S 2040 B
  • S 4050 or S 4050 HT AND/OR S 4060 or S 4060 HT
  • S 70200 or S 70200 HT
  • Probe Holders for Angle Beam Probes to Be Used for Weld Inspection
  • S 904050
Optional Accessories:
  • S 4010
  • S 799028 or S 799028 HT
  • SWA 996014
TRANSCAN - Inspection of Butt Joints for Defects Transversal to Weld Scanning from Both Sides and/or Above Machined Weld Enforcement (Standard HP 5/3) Order Code:
SWA 996606
  • Support of all A-Scan types (Full Wave / Neg Wave / Pos Wave rectification; RF) while scanning, recording and imaging defects
  • Support of Linear or DAC- , DGS- , TCG- normalized recording and imaging defects
  • FFT (Frequency Domain Signal Presentation) - additional feature for defects evaluation and / or pattern recognition
  • Testing Integrity / Coverage Imaging (Top View of Probe Manipulation Area) Showing of Actually Implemented Probe Trace
  • C-Scan (Top View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • B-Scan (Side View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • D-Scan (End View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • Versatile Color Palette for Defects Imaging
  • Postprocessing: Off-line Recovery and Play-Back of A-Scans; Echo Dynamic Pattern Recognition; Sizing of defects; Slicing and Filtering Images
  • Comprehensive Setup and Scanning Reporting, Direct Connection To any Type of USB or LAN Windows Printer
Required Accessories:
  • S 4030A or S 4030A HT
  • S 2040 B
  • S 4050 or S 4050 HT AND/OR S 4060 or S 4060 HT
  • S 70200 or S 70200 HT
  • Probe Holders for Angle Beam Probes to Be Used for Weld Inspection
  • S 904050
Optional Accessories:
  • S 4010
  • S 799028 or S 799028 HT
  • SWA 996014
EXPERT – High Resolution Scanning of Welds (Frontal Resolution - 0.25 mm / 0.01"), Scanning from One Side, Complete Raw Data Capturing Order Code:
SWA 996609
  • Support of all A-Scan types (Full Wave / Neg Wave / Pos Wave rectification; RF) while scanning, recording and imaging defects
  • Support of Linear or DAC- , DGS- , TCG- normalized recording and imaging defects
  • FFT (Frequency Domain Signal Presentation) - additional feature for defects evaluation and / or pattern recognition
  • Testing Integrity / Coverage Imaging (Top View of Probe Manipulation Area) Showing of Actually Implemented Probe Trace
  • C-Scan (Top View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • B-Scan (Side View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • D-Scan (End View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • Versatile Color Palette for Defects Imaging
  • Postprocessing: Off-line Recovery and Play-Back of A-Scans; Echo Dynamic Pattern Recognition; Sizing of defects; Slicing and Filtering Images
  • Comprehensive Setup and Scanning Reporting, Direct Connection To any Type of USB or LAN Windows Printer
Required Accessories:
  • S 4030A or S 4030A HT
  • S 2040 B
  • S 4050 or S 4050 HT AND/OR S 4060 or S 4060 HT
  • S 70200 or S 70200 HT
  • Probe Holders for Angle Beam Probes to Be Used for Weld Inspection
  • S 86000
Optional Accessories:
  • S 4010
  • S 799028 or S 799028 HT
  • SWA 996014
NOZZLE – Inspection of Nozzle Welds, Scanning from One Side, Complete Raw Data Capturing Order Code:
SWA 996611
  • Support of all A-Scan types (Full Wave / Neg Wave / Pos Wave rectification; RF) while scanning, recording and imaging defects
  • Support of Linear or DAC- , DGS- , TCG- normalized recording and imaging defects
  • FFT (Frequency Domain Signal Presentation) - additional feature for defects evaluation and / or pattern recognition
  • Testing Integrity / Coverage Imaging (Top View of Probe Manipulation Area) Showing of Actually Implemented Probe Trace
  • C-Scan (Top View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • B-Scan (Side View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • D-Scan (End View of Weld and Heat Affected Zone either Global or Sliced - switcheable)
  • Versatile Color Palette for Defects Imaging
  • Postprocessing: Off-line Recovery and Play-Back of A-Scans; Echo Dynamic Pattern Recognition; Sizing of defects; Slicing and Filtering Images
  • Comprehensive Setup and Scanning Reporting, Direct Connection To any Type of USB or LAN Windows Printer
Required Accessories:
  • S 4030A or S 4030A HT
  • S 2040 B
  • S 4050 or S 4050 HT AND/OR S 4060 or S 4060 HT
  • S 70200 or S 70200 HT
  • Probe Holders for Angle Beam Probes to Be Used for Weld Inspection
  • S 904050
Optional Accessories:
  • S 4010
  • S 799028 or S 799028 HT
  • SWA 996014
  • S 86000
TOFD – TOFD Inspection, Complete Raw Data Capturing Order Code:
SWA 996610
Averaging A-Scans whilst recording as per operator's selection
Recording of complete sequence of A-Scans along with TOFD map
Off-line evaluation of TOFD Map featured with:
  • Improvement of near to surface resolution through removal of lateral wave and back echo records from TOFD Map
  • Linearization and straightening of TOFD Map
  • Increasing contrast of TOFD images through varying Gain and rectification
  • A-Scan sequence analysis
  • Defects pattern recognition and sizing

Comprehensive Setup and Scanning Reporting, Direct Connection To any Type of USB or LAN Windows Printer
Required Accessories:
  • S 4030A or S 4030A HT
  • S 2040 B
  • 4060 or S 4060 HT
  • S 70200 or S 70200 HT
  • S 450000
  • S 799017
CORROMAP – Inspection with Straight Beam Ultrasonic Probes for Corrosion Mapping, Complete Raw Data Capturing Order Code:
SWA 996608
  • Support of all A-Scan types (Full Wave / Neg Wave / Pos Wave rectification; RF) while scanning, recording and imaging the Thickness / Corrosion Map
  • Support of Linear or DAC- , DGS- , TCG- normalized recording and imaging of Thickness / Corrosion Map
  • FFT (Frequency Domain Signal Presentation) - additional feature for defects evaluation and / or pattern recognition
  • Testing Integrity / Coverage Imaging (Top View of Probe Manipulation Area) Showing of Actually Implemented Probe Trace
  • C-Scan (Top View - Thickness / Corrosion Map either Global or Sliced - switcheable)
  • B-Scan (Side View - Thickness / Corrosion Profile either Global or Sliced - switcheable)
  • D-Scan (End View - Thickness / Corrosion Profile either Global or Sliced - switcheable)
  • Versatile Color Palette for Thickness / Corrosion Mapping
  • Postprocessing: Off-line Recovery and Play-Back of A-Scans; Echo Dynamic Pattern Recognition; Sizing of defects; Gate Manipulation - Rebuild C-, B-, and D-Scan views for various Gate Settings; Statistical Analysis; Slicing and Filtering Images
  • Comprehensive Setup and Scanning Reporting, Direct Connection To any Type of USB or LAN Windows Printer
Required Accessories:
  • S 4030A or S 4030A HT
  • S 2040 B
  • 4060 or S 4060 HT
  • S 70200 or S 70200 HT
  • Probe Holders for Angle Beam Probes to Be Used for Inspection
Optional Accessories:
  • S 4010
  • S 799028 or S 799028 HT
  • SWA 996014
CORROMAP CU – Inspection with Sraight Beam Ultrasonic Probes for Corrosion Mapping - Scanning above Tubular or Quasi-Tubular Surface (Curvature Radius 40 - 400 mm), Complete Raw Data Capturing Order Code:
SWA 996608 CU
  • Support of all A-Scan types (Full Wave / Neg Wave / Pos Wave rectification; RF) while scanning, recording and imaging the Thickness / Corrosion Map
  • Support of Linear or DAC- , DGS- , TCG- normalized recording and imaging of Thickness / Corrosion Map
  • FFT (Frequency Domain Signal Presentation) - additional feature for defects evaluation and / or pattern recognition
  • Testing Integrity / Coverage Imaging (Top View of Probe Manipulation Area) Showing of Actually Implemented Probe Trace
  • C-Scan (Unfolded Top View - Thickness / Corrosion Map either Global or Sliced - switcheable)
  • B-Scan (Unfolded Side View - Thickness / Corrosion Profile either Global or Sliced - switcheable)
  • B-Scan (Real Shape Side View - Thickness / Corrosion Profile either Global or Sliced - switcheable)
  • D-Scan (End View - Thickness / Corrosion Profile either Global or Sliced - switcheable)
  • Versatile Color Palette for Thickness / Corrosion Mapping
  • Postprocessing: Off-line Recovery and Play-Back of A-Scans; Echo Dynamic Pattern Recognition; Sizing of defects; Gate Manipulation - Rebuild C-, B-, and D-Scan views for various Gate Settings; Statistical Analysis; Slicing and Filtering Images
  • Comprehensive Setup and Scanning Reporting, Direct Connection To any Type of USB or LAN Windows Printer
Required Accessories:
  • S 4030A or S 4030A HT
  • S 2040 B
  • 4060 or S 4060 HT
  • S 70200 or S 70200 HT
  • Probe Holders for Angle Beam Probes to Be Used for Inspection
  • S 89000
Optional Accessories:
  • S 4010
  • S 799028 or S 799028 HT
  • SWA 996014
  • S86000
MULTISCAN-COMBO - S Inspection with Straight Beam Single Element or Dual Ultrasonic Probes for Internal Defects with Tomographical and 3D Data Presentation and User Defined Mapping Scheme, Complete Raw Data Capturing Order Code:
SWA 996613
  • Support of all A-Scan types (Full Wave / Neg Wave / Pos Wave rectification; RF) while scanning, recording and imaging defects
  • Support of Linear or DAC- , DGS- , TCG- normalized recording and imaging defects
  • FFT (Frequency Domain Signal Presentation) - additional feature for defects evaluation and / or pattern recognition
  • Testing Integrity / Coverage Imaging (Top View of Probe Manipulation Area) Showing of Actually Implemented Probe Trace
  • Pulse Echo Amplitude / Distance C-Scan (Top View of Scanning Area either Global or Sliced - switcheable)
  • Pulse Echo B-Scan (Side View of the Scanning Area either Global or Sliced - switcheable)
  • Pulse Echo D-Scan (End View of the Scanning Area either Global or Sliced - switcheable)
  • Through Transmission / Back Echo Attenualtion Amplitude C-Scan (Top View of Scanning Area)
  • Versatile Color Palette for Defects Imaging
  • Postprocessing: Off-line Recovery and Play-Back of A-Scans; Echo Dynamic Pattern Recognition; Sizing of defects; Gate Manipulation - Rebuild C-, B-, and D-Scan views for various Gate Settings; Statistical Analysis; Slicing and Filtering Images
  • Comprehensive Setup and Scanning Reporting, Direct Connection To any Type of USB or LAN Windows Printer
Required Accessories:
  • S 4030A or S 4030A HT
  • S 2040 B> 4060 or S 4060 HT
  • S 70200 or S 70200 HT
  • Probe Holders for Straight Beam Probes to Be Used for Inspection
Optional Accessories:
  • S 4010
  • S 799028 or S 799028 HT
  • S86000
  • 554230 AND/OR S 554231 AND/OR S 554232 AND/OR S 554233
MULTISCAN-COMBOS-CU Order Code:
SWA 996613 CU
  • Support of all A-Scan types (Full Wave / Neg Wave / Pos Wave rectification; RF) while scanning, recording and imaging defects
  • Support of Linear or DAC- , DGS- , TCG- normalized recording and imaging defects
  • FFT (Frequency Domain Signal Presentation) - additional feature for defects evaluation and / or pattern recognition
  • Testing Integrity / Coverage Imaging (Top View of Probe Manipulation Area) Showing of Actually Implemented Probe Trace
  • Pulse Echo Amplitude / Distance C-Scan (Top View of Scanning Area either Global or Sliced - switcheable)
  • Pulse Echo B-Scan (Unfolded Side View of the Scanning Area either Global or Sliced - switcheable)
  • Pulse Echo B-Scan (Real Shape Side View of the Scanning Area either Global or Sliced - switcheable)
  • Pulse Echo D-Scan (End View of the Scanning Area either Global or Sliced - switcheable)
  • Through Transmission / Back Echo Attenualtion Amplitude C-Scan (Top View of Scanning Area)
  • Versatile Color Palette for Defects Imaging
  • Postprocessing: Off-line Recovery and Play-Back of A-Scans; Echo Dynamic Pattern Recognition; Sizing of defects; Gate Manipulation - Rebuild C-, B-, and D-Scan views for various Gate Settings; Statistical Analysis; Slicing and Filtering Images
  • Comprehensive Setup and Scanning Reporting, Direct Connection To any Type of USB or LAN Windows Printer
Required Accessories:
  • S 4030A or S 4030A HT
  • S 2040 B
  • 4060 or S 4060 HT
  • S 70200 or S 70200 HT
  • Probe Holders for Straight Beam Probes to Be Used for Inspection
  • S 89000
Optional Accessories:
  • S86000
  • S 554230 AND/OR S 554231 AND/OR S 554232 AND/OR S 554233
FLOORMAP - Fast Tank Floor / Shell Inspection for Pitting and Deep Corrosion Damages - Linear and/or Beam Swiveling Scanning with On-Line Image Reconstruction Order Code:
SWA 996634
  • Support of all A-Scan types (Full Wave / Neg Wave / Pos Wave rectification; RF) while scanning, recording and imaging defects
  • Support of Linear or DAC- , TCG- normalized recording and imaging defects
  • FFT (Frequency Domain Signal Presentation) - additional feature for defects evaluation and / or pattern recognition
  • Complete Coverage of Whole Region Of Interest through Non Mechanically Encoded Linear and/or Beam Swiveling Scanning
  • CB-Scan (Top View - of Area of Interest)
  • Versatile Color Palette for Defects Imaging
  • Postprocessing: Off-line Recovery and Play-Back of A-Scans; Echo Dynamic Pattern Recognition; Sizing of defects; Filtering and Normalization of CB-Scan Image
  • Comprehensive Setup and Scanning Reporting, Direct Connection To any Type of USB or LAN Windows Printer
Required Accessories:
  • S 4030A or S 4030A HT
  • S 2040B AND/OR S 2045B
  • S 4050 or S 4050 HT AND/OR S 4060 or S 4060 HT AND/OR S 4055 or S 4055 HT
  • S 70200 or S 70200 HT
  • S 544000 or S 544000 HT
Optional Accessories:
  • S 904050